Two Stage Heat Pump
with One Stage Emergency Heat
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, W1, Y1, Y2, O/B and G wires from the heat
pump to R/RC, C, W/E/AUX, Y, Y2, O/B/W2 and G terminals
on the wall plate, respectively
Single Stage Cool – Air Conditioner
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, Y1 and G wires from the Air Conditioner to R/RC, C, Y
and G terminals on the wall plate, respectively