Service Manual Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Outdoor Unit | 65
Bosch Thermotechnology Corp. | 04.2020
Data subject to change
8.20 Low pressure switch open (P6/J6)
Error Code J6/P6
Malfunction decision conditions If the sampling voltage is not 5V, the LED displays a failure code.
Supposed causes
f Wiring mistake
f Overload protector faulty
f System block
f Outdoor PCB faulty
Table 43
Troubleshooting:
Figure 63
Lo w p re ssu r e p r o t e ctio n enabled
h
t
ai
nt
Are the low pressure
protector and main control
board wired properly?
Method: Disconnect the connection
Measure the resistance of the
low pressure protector. If the
protector is normal the value is
0. Does a problem still exist?
Yes
Yes
Reconnect the low pressure
p r o t e cto r a n d m ain PCB
R eplace outdoor m ain PCB
Does a problem still exist?
No
Replace low pressure protector
No
Is the low
pressure protector
broken?
t
p
a
Is the outdoor ambient
tem pera ture too low?
No
o
t
t
Sto p th e u n it Yes
O
Open the valve core of the
high pressure valve
No
s
Is the valve core of the
high pressure valve fully
opened?
i
i
Is the indoor fan running
properly in cooling mode?
o
a
i
o
n
i
au
a
eso
v
e
Refer to the solution to the malfunction
of fan speed being out of control. Find
the cause and resolve the problem.
No
Yes
Yes
Vacuum the system and
weigh-in refrigerant as per
the system requirement
No