Do you have a question about the Bosch BOVB36-18 and is the answer not in the manual?
Cooling Capacity (BTU) | 36, 000 |
---|---|
SEER | Up to 18 |
Voltage (V) | 208/230 |
Refrigerant | R-410A |
Heating Capacity | 36, 000 BTU |
Cooling Capacity | 36, 000 BTU |
Power Supply | 208/230V, 1 Phase, 60Hz |
Provides essential safety warnings and guidelines for installation and operation.
Outlines requirements for outdoor unit placement, clearances, and proximity.
Step-by-step instructions for brazing refrigerant lines, including pipe preparation.
Procedure for pressurizing lines with nitrogen and checking for leaks using a solution.
Steps for evacuating the system using a vacuum pump and micron gauge.
Specifies requirements for the high voltage power supply, matching the equipment nameplate.
Instructions for installing a separate disconnect switch for the outdoor unit.
A sequence of steps to safely start up the installed heat pump system.
Describes the weigh-in method for system charging, especially when other methods are not feasible.
Explains subcooling method for charging above 55°F outdoor temperature.
A table detailing error codes, their descriptions, and potential sensors involved.
Flowcharts and guidance for diagnosing and resolving specific error codes.