EasyManua.ls Logo

Bosch C 950 - Page 17

Bosch C 950
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation instructions
17
C 950/C 1050 (Pro TL 175 C/199 C) – 6 720 805 440 (2019/10)
Table 6 PVC concentric vent part breakdown
Fig. 9 Concentric vent kit example
[1] Exhaust
[2] Combustion air
[3] Roof boot/flashing (field supplied)
[4] Exhaust pipe
[5] Drain tee (196061, included in concentric vent kits) as
required. See chapter 4.3.2.
[6] Intake pipe
[7] Concentric vent kit (196016)
[8] Maintain 12 in. (18 in. for Canada) minimum clearance
above highest anticipated snow level maximum of 24 in.
above roof
Description Length Kit part
no. and
quantity
196016
3- In. Rain Cap N/A 1
4- In. Diameter SDR-26 Pipe 24 In. long 1
3- In. Y
Concentric Fitting
N/A 1
2- ½ In. Diameter SDR-26 Pipe 37-1/8 in.
long
1
3- In. Condensate drain Tee N/A 1
1.5- In. Condensate drain bushing N/A 1

Table of Contents

Other manuals for Bosch C 950

Related product manuals