EasyManua.ls Logo

Bosch C 950 - Gas Piping & Connections

Bosch C 950
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation instructions
C 950/C 1050 (Pro TL 175 C/199 C) – 6 720 805 440 (2019/10)
40
Fig. 31 Distance between support boards
[1] Studs 16" (406mm) on center
Fig. 32 Leveling wall mounting bracket
Fig. 33 Mounting the heater
CAUTION:
Personal injury and property damage.
Appliance must be installed vertically.
4.8 Gas piping & connections
Before connecting the gas supply, check the rating plate on the
right side of the heater to be sure that the heater is rated for the
same gas to which it will be connected.
In the United States: The installation must conform with local
codes or, in the absence of local codes, the National Fuel Gas
Code ANSI Z223.1/NFPA 54.
In Canada: The Installation must conform to CGA B149
INSTALLATION CODES and/or local installation codes.
DANGER:
Explosion hazard!
DO NOT connect to an unregulated or high pressure
propane line or to a high pressure commercial natural gas
line.
6720608158-64.1AL
6720608158-05.1AL6720608158-05.1AL

Table of Contents