Operation
39
Climate 5000 L • Climate 5000i U/L – 6721841496 (2024/06)
3.8.3 Weekly event timer
Setting timer
Up to 8 events can be set for each day to change the operating mode,
temperature and fan speed.
Keep pressing the TIMER key until WEEK 2 appears in the display.
Confirm with key.
Press the . or / key to select the weekday.
Confirm with key.
Press the . or / key to select the setting time, main operating
mode, temperature or fan speed for the event.
Confirm with key.
Make the setting and press the key to confirm or the DAY OFF key
to delete the setting.
Repeat the procedure to define additional setting periods for this
day.
Follow the same procedure to program additional weekdays.
To delete the timer for the selected day:
Press the DAY OFF key.
Defining the setting time
Press the . or / key to adjust the time.
Confirm with key.
Selecting the main operating mode
Press the . or / key to select the main operating mode (
Table 42, [1], page 37) ).
Confirm with key.
The fan speed cannot be adjusted in automatic and dehumidification
mode.
Setting the room temperature
Press th . or / key to set the desired room temperature.
Confirm with key.
Fan step
Press the . or / key to adjust the fan step.
Confirm with key.
The temperature cannot be adjusted in Fan Mode.
Activating the timer
Press the TIMER key until WEEK 2 appears in the display.
The timer is now switched on. The unit will adjust itself automatically
on these selected times and days.
Deactivating the timer
Press the Kor TIMER key for several seconds.
3.8.4 Additional settings for weekly timer
Provisionally disabling the timer
To disable the timer on selected days only:
Press the TIMER key until WEEK 1 or WEEK 2 appears in the display.
Press the key.
Press the . or / key to select the weekday.
Press the DAY OFF key.
The selected day is no longer displayed.
The timer is deactivated for the days that are not displayed until the day
has passed.
Press the DAY OFF key again to display the day once again.
Repeat the above if necessary for the other days.
Adopting (copying) settings from one day to another day
Press the TIMER key until WEEK 1 or WEEK 2 appears in the display.
Press the key.
Press the . or / key to select the day whose settings should be
adopted.
Press the COPY key to copy the settings.
CY appears on the display.
Press the . or / key to select the day to which the settings should
be copied.
Press the COPY key to insert the copied settings.
The selected weekday flashes briefly as confirmation.
Repeat the above steps if necessary to copy the information to other
days.
Press the key to adopt the changes.
3.9 Other functions
3.9.1 Switching the key sound on/off
To switch the the key sound of the wired room controller on or off:
Press and hold the and FUNC. keys for three seconds.
3.9.2 Turbo cool/Turbo heat
When Turbo cool/Turbo heat is active, the indoor unit operates at
maximum power to heat or cool the room quickly.
Turbo Cool:
Switch on cooling mode.
Press the FUNC. key.
Confirm with key.
Turbo Heat:
Switch on heating mode.
Press the FUNC. key.
Confirm with key.
Exiting the function:
Press the FUNC. key again.
Confirm with key.
3.9.3 Noise reduction (Silent Mode)
This function reduces the noises emitted by the indoor and outdoor unit
when it is in operation. This is particularly advantageous at night, if you
need to show consideration for your neighbours.
During operation, press the key for 2 seconds.
Exiting the function:
Press the key again for 2 seconds.
-or-
Press the K key, Mode key, Turbo key or Clean key.
When the outdoor unit is in quiet mode, it may not be possible to achieve
the required cooling/heating capacity because the compressor operates
at a low frequency.
3.9.4 Sleep mode
The purpose of this function is to save energy during idle times. After an
hour, the device heats or cools less intensely. To do this, the set
temperature is changed by 1 °C. After two hours, the set temperature
changes by a further 1 °C. Then it remains at the new temperature.