Product Information
Climate 5000i U/L – 6721841495 (2021/10)
34
1.3 Notices regarding these instructions
The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2Product Information
2.1 Declaration of conformity
The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2 Specifications of remote control
Table 2 Specifications of remote control
2.3 Operating temperature range
Table 3
The built-in protection device may prevent the appliance from operating
at temperatures outside the above range.
If the humidity is more than 80 %, condensation may form at the air
outlet. To prevent this, open the vertical ventilation flaps as wide as
possible (vertical relative to the ground) and set a high fan output.
2.4 Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
unit is hermetically sealed. The following information on the refrigerant
complies with the requirements of EU Regulation No. 517/2014 on
fluorinated greenhouse gases.
Notice for the user: If your installer adds refrigerant, he enters the added
fill volume and the total amount of the refrigerant in the following table.
Table 4 F-Gas
Power infeed 2 AAA batteries
Signal range 8 m
Permissible ambient
temperature
16... 30 °C
Room temperature Outside temperature
Cooling 16 ... 32 °C −15... 50 °C
Heating 0 ... 30 °C −15... 24 °C
Dehumidifying 10... 32 °C
Product type Rated cooling
output
[kW]
Rated heating
output
[kW]
Refrigerant
Type
Global
warming
potential
(GWP)
[kg Co
2
equ.]
CO
2
equivalent
of initial
charge
Initial
charge
volume
[kg]
Additional fill
volume for
pipe length
L
1)
[g/m]
1) Total pipe length L in metres (if L > 5 m simple path from outdoor unit to indoor unit).
Total charge
volume during
commissioning
[kg]
CL5000L 35 E 3.52 3.81 R32 675 0.49 0.72 12
CL5000L 53 E 5.28 5.57 R32 675 0.78 1.15 12
CL5000L 70 E 7.03 7.62 R32 675 1.01 1.5 12
CL5000L 88 E 8.79 9.38 R32 675 1.35 2.0 24
CL5000L 105 E 10.55 11.72 R32 675 1.62 2.4 24
CL5000L 105 E-3 10.55 11.72 R32 675 1.62 2.4 24
CL5000L 125 E 12.02 13.48 R32 675 1.89 2.8 24
CL5000L 140 E-3 14.07 16.12 R32 675 1.96 2.9 24
CL5000L 160 E-3 15.24 18.17 R32 675 2.03 3.0 24