Troubleshooting/Problem Solving
P8 Upper Element has no current 1. Check power voltage whether in normal work-
ing range.
2. Check wire connections.
3. Check temperature limiters (TCOs).
4. Check upper heating element for damage.
5. Check the wire whether through current
sensor in PCB.
6. Check resistance through element (15.8 1
amp).
PA Lower Element has no current Check wire connections from sensor to control
board.
Check power voltage whether in normal working
range.
Check power code connect correct or not.
Check temperature limiters (TCOs).
Check lower element for damage.
Check resistance through element (15.8 1
amp)
Error code Meaning Solutions
Table 6