EasyManua.ls Logo

Bosch Condens 2000 W - Sensor (NTC) Values; Flow Temperature Sensor Values; DHW Temperature Sensor Values; Flue Gas Safety Sensor Values

Bosch Condens 2000 W
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Failures / Errors | 25
3.4 Sensor (NTC) Values
3.4.1 Flow Temperature Sensor
3.4.2 Domestic Hot Water Temperature Sensor
3.4.3 Flue Gas Safety Temperature Sensor ( Behind
Burner)
Temperature (°C)
Measure Tolerance ±%10 Resistance (Ω)
20 14 772
25 11 981
30 9 786
35 8 047
40 6 653
45 5 523
50 4 608
55 3 856
60 3 243
65 2 744
70 2 332
75 1 990
80 1 704
85 1 464
90 1 262
95 1 093
100 950
Tab. 4
DHW Temperature Sensor
C )
Resistance (Ω)
0 33 242
10 19 947
20 12 394
30 7 947
40 5 242
50 3 548
60 2 459
70 1 740
80 1 256
90 923
Tab. 5
Temperature (°C)
Measure Tolerance ±%10
Resistance (Ω)
0 27 936
20 12 136
40 5 774
60 2 967
80 1 629
100 947
120 578
140 387
160 244
180 168
200 119
210 101
220 86
240 64
260 49
Tab. 6

Related product manuals