Robert Bosch Engineering and Business Solutions Private Limited | September 19, 2020
Annexure
1 Document Details
Subject iTraMS CCU User Manual
Status
Approved By
Released By
Confidentiality
Public
2 Document Revision History
DATE
VERSION NUMBER
DESCRIPTION NUMBER SIGNATURE OF
APPROVER
September 19, 2020 1.0
3 Abbreviations Used
Connectivity Control Unit
Electro Magnetic Compatability
Global Navigation Satellite System
Intelligent Transport Management System
Original Equipment Manufacturer
Printed Circuit Board Assembly
Wireless Local Area Network
Wideband Code Division Multiple Access
4 EMC Recommendations
Do not route the sensitive signals in parallel to high tension wires (ignition, Digital I/O).
Wire from CCU to Vehicle battery should be as short as possible.
Avoid loops in the routing.
CCU ground shall be as short as possible fixed to chassis or directly to battery ground
For CAN wiring, it is recommended to use a twisted pair (Figure 3).