Installation Guide
Addressable Smoke
Detector Base
D278S/D298S
Question and Answer IconNeed help?

Do you have a question about the Bosch D278S and is the answer not in the manual?

Summary

Overview of D278 S;D298 S Detector Bases

Overview of Detector Bases

Details the D278S/D298S addressable smoke detector bases, compatibility, and features.

Mounting the Detector Base

Wiring Instructions

Terminal Connections

Guidance on connecting wires to terminals, including power loop and ground connections.

Wire Size Requirements

Details acceptable wire gauges based on circuit length and number of bases.

Wiring Multiple Detector Bases

Illustrates how to wire multiple D278S or D298S bases in a system.

D298 S and PAM-4 Auxiliary Relay Module Wiring

Wiring diagram and table for connecting the D298S with the PAM-4 Auxiliary Relay Module.

Base POPIT Address Configuration

Setting Base POPIT Addresses

Explains how to determine and set the unique POPIT address for each base using DIP switches.

Product Specifications

Electrical Specifications

Provides electrical specifications including voltage range, idle current, and alarm current for the bases.

Summary

Overview of D278 S;D298 S Detector Bases

Overview of Detector Bases

Details the D278S/D298S addressable smoke detector bases, compatibility, and features.

Mounting the Detector Base

Wiring Instructions

Terminal Connections

Guidance on connecting wires to terminals, including power loop and ground connections.

Wire Size Requirements

Details acceptable wire gauges based on circuit length and number of bases.

Wiring Multiple Detector Bases

Illustrates how to wire multiple D278S or D298S bases in a system.

D298 S and PAM-4 Auxiliary Relay Module Wiring

Wiring diagram and table for connecting the D298S with the PAM-4 Auxiliary Relay Module.

Base POPIT Address Configuration

Setting Base POPIT Addresses

Explains how to determine and set the unique POPIT address for each base using DIP switches.

Product Specifications

Electrical Specifications

Provides electrical specifications including voltage range, idle current, and alarm current for the bases.

Bosch D278S Specifications

General IconGeneral
TypePhotoelectric Smoke Detector
StandardsUL 268
Operating Temperature0°C to 49°C (32°F to 120°F)
Operating Humidity0 to 95% RH, non-condensing
Sound Output≥85dB at 3m
Dimensions130mm x 56mm
Alarm Sound Level≥85dB at 3m