EasyManua.ls Logo

Bosch D720 - System Walk Test; COMMAND 44: Performing Walk Test

Bosch D720
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Walk Test
I have this feature.
I do not have this feature.
This feature requires a passcode.
Use this function to test command centers, detection devices, and
sounders (both interior and exterior) to be certain they function properly.
You can review untested points at your command center to help pin-point
any problems.
You cannot arm your system while in the walk test mode, and no alarm
reports are sent to your security company unless a 24-hour point is
activated (such as fire or panic).
The AC will be disabled for 4 minutes in order to test the system’s
battery power. If the battery cannot maintain the system for the 4
minute period, the command center will appear to go dead. If this
happens, contact your security company. At the end of the 4 minute
period, AC is returned to the system and the panel restores.
To test individual detection devices, simply activate sensors and open
protected doors and windows one-at-a-time. As each detection device is
faulted, the Command Center emits a brief tone and the display indicates
that the point has been tested. This verifies that each detection device is
working properly.
COMMAND 4 4
To use Walk Test:
1. Ensure that your security system is idle.
2. Press the COMMAND bar. The Command Mode indicator light comes
on.
3. Press the 4 key, and then the 4 key again. Audible devices (both
interior and exterior) sound the burglary bell.
4. After silencing the audible devices, you may test detection devices.
Open a door or window, or activate a motion sensor. Each time a
detection device has been tested, the Command Center will beep for 2
seconds. The Command Center display panel indicates the point which
you have faulted. This verifies that the detection device is working
properly.
5. To end the Walk Test, press any numeric key on the Command Center.
If no activity occurs on the system for 20 minutes, the Walk Test will
end automatically.