D9412GV2/D7412GV2 Release Notes for Version 7.09
F01U003637-06 Page 12 © 201313 Bosch Security Systems, Inc.
4: Parameters for Heartbeat Poll
Configuration in Version 7.03
1
1 30 6 2 to 19
1 30 8 2 to 12
1 30 10 2 to 8
1 30 12 2 to 5
1 30 14 2 to 3
1 60 6 2 to 14
1 60 8 2 to 8
1 60 10 2 to 5
1 60 12 2
2
2
2
1 90 6 2 to 9
1 90 8 2 to 4
1 90 10 2
1 120 6 2 to 4
1 145 5 2
2
2
2
2
2
2
2
2
2
1
The parameters in this table are for Version 7.03
.
2
Recommended settings for the corresponding
number of IP paths.
• Corrections allow the
Path # Retry Count
value to be used as the number of retries
instead of the number of transmission
attempts.
• When the control panel disconnects from an
RPS session using the network and the
“Reset Panel” checkbox is set, the control
panel now logs a Remote Reset event instead
of a Reboot Event.
• Corrections now prevent the D9412GV2 and
D7412GV2 Control Panels from performing a
watchdog reset when an area is armed with
more than 75 manually bypassed points or
has more than 75 force bypassed points.
• Corrections now prevent the D9412GV2 and
D7412GV2 Control Panels from performing a
watchdog reset when an area with
A# Area
Type
set to Shared is individually armed.
Shared areas should not be individually
armed or disarmed.
• Corrections now prevent a duress passcode
from being accepted by a keypad currently in
an area that has
A# Duress Enable
set to No.
If the Duress feature is used, A
# Duress
Enable
should be set to Yes for all areas.
• The alternate function of Area 6 Silent Alarm
Relay parameter was removed. To enable Fire
Trouble Resound support, use
GV2AUX→MISCELLANEOUS→Fire Trouble
Resound.
• The alternate function of Area 5 Silent Alarm
Relay parameter was removed. The Ground
Fault detection feature is solely enabled by
closing Switch S4 on the D9412GV2 and
D7412GV2 Control Panels.
• Changes now suppress the ALARM SILENCED
message when a user attempts to silence a
Ring Until Restored fire bell. A fire alarm
generated by a point with the Ring Until
Restored (
P# Ring Til Rst
) feature set to Yes
will sustain the fire bell until the sensor is
restored.
• Corrections ensure that acknowledged Silent
Alarms scroll correctly on the idle text
displays on the D1260 and D1260B Keypads.
• Corrections now allow a user’s token, with
L#
Disarm Level
set to 1, to disarm the interior
of all areas within the scope of the keypad
programmed at
D# CC# Scope
. The keypad
programmed at
D# CC# Scope
must have
CC# Passcode Follows Scope
set to Yes to
disarm the interior of all areas within scope.
• Corrections now allow the panel-wide
Communications Failure Relay output to
activate when events in Route Groups 2
through 4 do not reach the central station.
Previously this relay output activated only on
a communication failure for Route Group 1.
2.8 Version 7.02
• The Phone Line Supervision feature has
improved accuracy in detecting the phone
line.
• The Modem IIIa
2
product ID is changed to the
same ID as the G Series control panels,
allowing compatibility with non-Bosch central
station receivers.
2.9 Version 7.01
The following are corrections and changes made
since Version 6.60 in the G Series Control
Panels.