Battery Replacement
If the batteries are flat, the smoke detector will indicate this
with a short beep every 48 seconds and the red LED will also
flash three times every 48 seconds. Replace the batteries as
follows.
!
Caution!
Do not use 1.2 V batteries.
1. Remove the used batteries from the battery compartments
on the back of the detector head.
2. Insert three new LR6 batteries (mignon/AA) in the battery
compartments, observing the polarity shown.
i
Notice!
Once the batteries have been inserted, the red LED flashes ev-
ery 48 seconds, which signals that the device is ready for opera-
tion.
Technical Data
Sound pressure level at a
distance of 3 m
> 85 dB(A)
Power supply 3 x 1,5 V LR6 Alkaline batteries
(Mignon/AA)
Dimensions (diameter x
height) mm
120 x 44 mm
Protection category
(EN60529)
IP30
Permissible operating
temperature
0 °C to 50 °C
6.3
7
26
en | Safety FERION 3000 O
2013.01 | 3.0 | F.01U.249.483 User Guide Bosch Sicherheitssysteme GmbH