42
Cause Corrective Measure
Battery charge indicator (g), temperature warning and
“ERROR” indicator in the display
Temperature of the
measuring tool not within
the allowable charge-
temperature range.
Wait until the charge-
temperature range is reached.
Battery charge-control indicator (g) and “ERROR”
indication in the display
#BUUFSZ DIBSHJOH WPMUBHF
not correct
Check if the plug-in connection
has been established correctly
and if the battery charger is
operating properly. When the
unit symbol is flashing, the
battery is defective and must be
SFQMBDFECZB#PTDIBGUFSTBMFT
service.
Measuring result not plausible
The target surface does
not reflect correctly (e.g.
water, glass).
Cover off the target surface.
Laser beam output 19,
reception lens 20 or
camera 18 is covered.
,FFQUIFMBTFSCFBNPVUQVU19,
reception lens 20 and camera
18 clear.
Wrong reference level
set.
Select reference level that
corresponds to measurement.
Obstruction in path of
laser beam.
Laser point must be completely
on target surface.
Data transmission via USB interface not possible
.JDSP64#DBCMF Check the proper and tight seating
PGUIFNJDSP64#DBCMF
$IFDLUIFNJDSP64#DBCMFGPS
damage.
w ww . . co m