EasyManua.ls Logo

Bosch Greenstar Series - Contents

Bosch Greenstar Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Contents
3
Greenstar – 6721822579 (2021/01)
9 ZBR...-3A appliances (heating boiler) with DHW tank:
Thermal disinfection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
10 Boiler circulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
10.1 Pump anti-seize protection . . . . . . . . . . . . . . . . . . . . . . 54
10.2 Changing the pump curve of the boiler pump . . . . . . . . 54
11 Heatronic boiler control settings . . . . . . . . . . . . . . . . . . . . . . . 55
11.1 Guideline to service functions . . . . . . . . . . . . . . . . . . . . 55
11.2 Overview of the service functions . . . . . . . . . . . . . . . . . 56
11.2.1 First service level (press and hold the service
button until it lights up) . . . . . . . . . . . . . . . . . . . . . . . . . 56
11.2.2 Second service level (at first service level, service
button lights up, press ECO button and key pad
lock button simultaneously until 8.A appears) . . . . . . . 56
11.3 Description of the service functions . . . . . . . . . . . . . . . 56
11.3.1 First service level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
11.3.2 Second service level . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
12 Gas adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
12.1 Converting to a different gas type . . . . . . . . . . . . . . . . . 62
12.2 Installation location higher than 2,000 feet (610
m) above sea level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
12.3 Checking and setting the gas-air ratio (CO
2
or O
2
),
if required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
12.4 Dynamic gas pressure test port . . . . . . . . . . . . . . . . . . . 64
13 Flue gas test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
13.1 Emissions test button . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
13.2 Measuring CO content of flue gas . . . . . . . . . . . . . . . . . 64
14 Environmental protection and disposal. . . . . . . . . . . . . . . . . . 65
15 Inspection and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
15.1 Description of various steps. . . . . . . . . . . . . . . . . . . . . . 66
15.1.1 Calling up the latest fault (service function 6.A). . . . . . 66
15.1.2 Fresh water filter (only combi boiler ZWB...-3A) . . . . . 66
15.1.3 Plate type heat exchanger (only combi boiler
ZWB...-3A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
15.1.4 Checking electrodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
15.1.5 Burner servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
15.1.6 Heat exchanger block inspection and cleaning . . . . . . . 68
15.1.7 Cleaning condensate trap. . . . . . . . . . . . . . . . . . . . . . . . 69
15.1.8 Checking the mixer diaphragm . . . . . . . . . . . . . . . . . . . 69
15.1.9 Checking the expansion vessel . . . . . . . . . . . . . . . . . . . 70
15.1.10 Setting the boiler water pressure . . . . . . . . . . . . . . . . . 70
15.1.11 Testing system water quality . . . . . . . . . . . . . . . . . . . . . 70
15.1.12 Checking the electrical wiring. . . . . . . . . . . . . . . . . . . . 70
15.2 Maintenance and inspection checklist. . . . . . . . . . . . . . 71
16 Readings on the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
17 Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
17.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
17.2 Faults that are shown on the display . . . . . . . . . . . . . . .74
17.3 Faults that are not shown on the display . . . . . . . . . . . .76
17.4 Check sensor values. . . . . . . . . . . . . . . . . . . . . . . . . . . .77
17.4.1 Outdoor temperature sensor . . . . . . . . . . . . . . . . . . . . .77
17.4.2 Additional supply temperature limiter. . . . . . . . . . . . . .77
17.4.3 Supply temperature sensor, External supply
temperature sensor, DHW tank temperature
sensor, DHW temperature sensor . . . . . . . . . . . . . . . . .77
17.5 Replacement code plug . . . . . . . . . . . . . . . . . . . . . . . . .77
18 Commissioning log for the appliance . . . . . . . . . . . . . . . . . . .78

Table of Contents

Related product manuals