6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Operating Instructions | 49
▶ Remove the four screws that retain the cover plate to the
gas manifold, see fig. 47 (plate in grey color).
Fig. 47 Gas manifold
▶ Remove metal plate and seal.
▶ The 3 restrictor plates should be pre-assembled onto their
tray, but if loose in box, follow installation instructions, as
shown in fig. 48 and 49[1].
▶ Insert the LP conversion plate in the appropriate location
shown in fig. 48 and 49 [2].
Fig. 48 199kBTU appliance gas conversion kit
Fig. 49 160kBTU appliance gas conversion kit
▶ Tighten the four screws.
▶ Open the gas supply valve.
▶ Turn On the appliance.
▶ Check for gas leak (e.g. use leak detector fluid, like water
and soap, over and around the metal plate) and act
accordingly.
▶ Replace the front cover.
▶ Access the Technical Settings menu (section 6.6).
▶ Access to menu P7 Gas Type.
Display shows appliance gas type.
▶ Use the symbols or to choose gas type LPG.
▶ Touch the symbol .
The display blinks to confirm the change.
▶ Update “TYPE OF GAS” in the rating plate of the appliance
using the label provided with the conversion plates.
▶Confirm CO
2
and CO values and, if necessary, adjust Gas
and Air flow parameters, see chapter 8.11 for more
information.
CAUTION:
▶ All three flow restrictors and seal must
be assembled according to the fig. 48
and 49, to assure correct appliance
performance.
L’appareil passera par un processus
d’initialisation.