6 720 816 815 (2018/08)Greentherm T9800 SE 160/199 | SEC 199
Problem solving | 63
E7 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
E8 Error during ionization test. Electronic control unit
internal error.
Replace electronic control unit.
1)
E9 Thermal fuse [13] broken. Replace thermal fuse.
1)
EA Ignition failure. Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.11).
1)
EB Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
EC Flame lost during operation. Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.11).
1)
EE Gas valve modulation solenoid [7] disconnected. Check gas valve wire connection.
1)
If the problem persists:
Replace the gas valve and/or wire connections and/
or electronic control unit. For gas valve replacement
perform gas and air tuning ( section 8.11).
1)
EF Wrong gas connected (LP instead of NG) for
current appliance configuration.
Check gas type ( section 6.8).
1)
F2 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F3 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F7 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F8 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F9 Gas valve driver internal fault. Check gas valve wire connections.
1)
If the problem persists:
Replace the wire connections and/or electronic
control unit.
1)
FA Gas leakage in the gas path (gas valve or gas
manifold shut-off valves).
Replace the gas valve and/or gas manifold.
1)
After gas valve and/or gas manifold replacement
perform gas and air tuning ( section 8.11).
1)