Bosch applications manual | 06.2009BOSCH THERMOTECHNOLOGY CORPORATION
Bosch applications manual
| 15
7.1.2 Powerstream Pro electric point-of-use tankless water heater
PowerstreamPro point-of-use water heaters come in four models to
serve a wide range of applications. Finding the right model depends
upon your desired temperature and ow rate. See Section 2.1 to
nd the model best suited to your customer‘s needs. Flow controls
and faucet aerators can greatly enhance performance.
Note: Water heater must be lled with water and purged of air prior
to supplying power.
Symbols
Service valve
Sink
Flow direction
hot
hot
cold
Powerstream Pro
RP1P, RP2P, RP3P,
RP7P, RP9P
Note:
Drawing is not to scale.
RP12PT cannot be mounted sideways.
Cold water piping to fixtures not shown for clarity purposes.
hot
cold supply
hot
cold
Powerstream Pro
RP1P, RP2P, RP3P,
RP7P, RP9P, RP12PT
cold supply