EasyManua.ls Logo

Bosch ISM-BLQ1 User Manual

Bosch ISM-BLQ1
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© 2010 Bosch Security Systems, Inc. 4998153066 | 08 | 2010.10 | 1
Blue Line Q1
ISM-BLQ1
UL
Use only a Listed limited-power source.
ISM-BLQ1 è certi cato IMQ – Sistemi di sicurezza al primo
livello di prestazione. La certi cazione IMQ – Sistemi di
sicurezza decade nel caso di installazione del rilevatore con
gli snodi opzionali B328, B338, B335.
SBSC larmklass 3, miljöklass 2
SELV
Connect all wiring to a safety extra-low voltage (SELV) circuit only.
Anslut allt kablage endast till en säkerhetskrets med extra låg spänning (SELV).
Sluit alle bedrading uitsluitend aan op een circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité (TBTS).
Alle Drähte sind ohne Ausnahme an Niederspannung anzuschließen.
Collegare tutti i cavi esclusivamente a un circuito SELV (circuito di sicurezza a bassissima tensione).
Ligue todas as cablagens apenas a um circuito de segurança de tensão extra baixa (SELV).
Conecte el cableado únicamente a un circuito de seguridad para voltajes muy bajos (SELV).
仅限将所有的线路与安全极低电压(SELV)电路连接。
-29°C to +49°C (-20°F to +120°F )
For UL Listed installations, the temperature range is 0°C to +49°C
(+32°F to +120°F)
Pour les installations certi ées NFA2P, Température de fonctionnement
-10°C à +55°C
EN CLC/TS 50131-2-2 Grade 2
EN 50130-5 Environmental Class II
IP30 IK04 (EN 60529, EN 50102)
CNPP Test Report 470 3 008 01 0001
Certi cation NF A2P Type 2
Attestation NFA2P Type 2
2620002640 delivrée par
CNMIS SAS 75017 PARIS
CNPP Certi cation 27950 St Marcel
BE: INCERT: B509-0009
Current Draw: 10 mA @ 12 VDC
Standby Power: No internal standby battery.
For UL Listed product installations, provide 4 h (60
mAh) standby power from the control unit or by a UL
Listed burglary power supply.
Humidity: 0 to 95% non-condensing (0 to 85% UL installations)
Strömförbrukning: 10 mA @ 12 VDC
Vilolägesförbrukning: Inget internt vilolägesbatteri.
Relativ luftfuktighet: 0 till 95 % luftfuktighet, icke-kondenserande
Stroomverbruik: 10 mA op 12 VDC
Relatieve vochtigheid: 0 tot 95% niet condenserend
Consommation :
10 mA à 12 Vcc en veille / en alarme source limitée
en puissance, ondulation résiduelle 1 V
Humidité : de 0 à 95% sans condensation
Stromaufnahme: 10 mA bei 12 V DC
Luftfeuchtigkeit: 0 bis 95%, nicht-kondensierend
Assorbimento di corrente: 10 mA @ 12 V—
Umidità: Da 0 a 95% senza condensa
Consumo: 10 mA a 12 VCC
Humidade: 0 a 95% sem condensação
Consumo de corriente: 10 mA a 12 Vcc
Humedad: de 0 a 95% sin condensación
最大电流: 10 毫安 @ 12伏直流
湿度: 0至95%非冷凝
48 mm
(1.9 in.)
132 mm
(5.2 in.)
61 mm
(2.4 in.)
Question and Answer IconNeed help?

Do you have a question about the Bosch ISM-BLQ1 and is the answer not in the manual?

Bosch ISM-BLQ1 Specifications

General IconGeneral
BrandBosch
ModelISM-BLQ1
CategoryAccessories
LanguageEnglish

Summary

Compliance and Certifications

IMQ Certification Details

Details IMQ certification for security systems, noting potential invalidation with optional accessories.

NF A2P Certification

Details NF A2P Type 2 certification, including issuing bodies and reference numbers.

SBSC and INCERT Approval

Specifies SBSC alarm class 3, environmental class 2, and INCERT approval number.

UL and SELV Requirements

Mandates using UL Listed power source and SELV circuits for UL installations.

Technical Operating Parameters

Current Draw and Standby

Details current draw at 10 mA @ 12 VDC and notes no internal standby battery.

Humidity Tolerance

Specifies humidity tolerance from 0 to 95% non-condensing.

Temperature Range

Defines the operating temperature range as -29°C to +49°C (-20°F to +120°F).

Installation Steps and Diagrams

Mounting and Wiring

Illustrates installation steps, including mounting and wiring connections for the device.

Tamper Contact Connection

Details the tamper contact connection requirements to a 24-hour protection circuit.

Module and Relay Functions

Alarm Relay Specifications

Provides specifications for the alarm relay, including maximum ratings and contact resistance.

Digital Alarm Module

Explains the activation of optional plug-in modules via digital alarm signals.

Pet Immunity Feature

Describes how to enable the look-down zone for non-pet installations.

Testing and Detection Zones

Walk Test Procedure

Outlines the walk test procedure for the detector, including power-up wait time.

Detector Testing Recommendation

Recommends annual testing of the detector by an installer.

Look-down Zone Coverage

Details the coverage area and characteristics of the look-down zone.