3.5 Removing the upper heating elements
1. Remove the housing.
2. Discharge the HV capacitor.
3. Unscrew the cooling fan assembly, and lift out.
4. Disconnect the magnetron and the H.V. transformer.
5. Unscrew and remove magnetron and H.V. transformer.
6. Disconnect the wiring above the upper heat protector assembly.
7. Unscrew the upper heat protector assembly from the cavity upper
plate, and lift out carefully.
7. Disconnect the heating elements.
8. Remove the hex nuts on the right side of cavity and on the upper of
cavity.
9. Lift out the upper heating elements from the cavity.
Page 13 of 23 pages
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
______________________________________________________________________________________________________________________________________________________________________________
Copyright by BSH Home Appliances Corporation 1901 Main Street, Suite 600, Irvine CA 92614 700_ 58300000192890_ARA_EN_A 800 444-9091