2.3 High-voltage transformer
This transformer supplies the heater voltage for the magnetron and
the operating voltage for doubling the voltage.
• Input voltage 230 V
• Heater voltage approx. 3.3 V
• Operating voltage approx. 2300 V
The operating voltage cannot be measured!!
Heater voltage of
approx. 3.3V
Primary side 230V
of input voltage