2.3 High-voltage transformer
This transformer supplies the heater voltage for the magnetron and
the operating voltage for doubling the voltage.
• Input voltage 230 V
• Heater voltage approx. 3.3 V
• Operating voltage approx. 2300 V
The operating voltage cannot be measured!!
Heater voltage of
approx. 3.3V
Primary side 230V
of input voltage
Page 6 of 23 pages
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
______________________________________________________________________________________________________________________________________________________________________________
Copyright by BSH Home Appliances Corporation 1901 Main Street, Suite 600, Irvine CA 92614 700_ 58300000192890_ARA_EN_A 800 444-9091