ICP-CP508 | User's Guide | 3.0 ICP-CP508LW LCD Codepad Indicators EN | 4
Bosch Security Systems, Inc. | 9/08 | F01U089856-01
2.6 Audible Indicators
The codepad provides a number of audible
indications as defined in Table 6.
Table 6: Audible Indicators
Audible Indicator Definition
One short beep A button was pressed on the
codepad, or Exit Time ended when
arming in STAY Mode 1 or STAY
Mode 2.
Two short beeps The system accepted your code.
Three short beeps The system executed the requested
function.
One long beep Exit Time ended when arming in
AWAY Mode, or the requested
operation was denied or aborted.
One short beep
every sec
Walk Test Mode is currently active,
or warning before automatic arming
takes place.
One short beep
every 2 sec
Telephone Monitor Mode is active.
One short beep
every min
There is a system fault to be
acknowledged.
3.0 ICP-CP508LW LCD
Codepad Indicators
Refer to Figure 2 on page 2.
3.1 Zone Indicators
1 2 3 ….
The zone indicators (1 to 8) display the
status of the zones. Table 1 lists the various
situations that the indicators show.
Table 1 : Zone Indicator
Zone Indicator Definition
On Zone is unsealed.
Off Zone is sealed.
Flashing Fast
(0.25 sec on/
0.25 sec off)
Zone is in alarm condition.
Flashing Slow
(1 sec on/
1 sec off)
Zone is manually isolated or
selected to be isolated.
3.2 AWAY Indicator
The AWAY indicator appears when the
system is armed in AWAY Mode. The
AWAY indicator also flashes in unison with
the STAY indicator when programming
various options throughout this user’s guide.
Table 2: AWAY Indicator
AWAY
Indicator
Definition
On System is armed in AWAY Mode.
Off System is not armed in AWAY Mode.
3.3 STAY Indicator
The STAY indicator appears when the system
is armed in STAY Mode 1 or STAY Mode 2.
The STAY indicator also flashes in unison with
the AWAY indicator when programming
various options throughout this user’s guide.
Table 3: STAY Indicator
STAY
Indicator
Definition
On System is armed in STAY Mode 1 or
STAY Mode 2.
Off System is not armed in STAY Mode 1
or STAY Mode 2.
Flashing twice
a sec
Zone Isolating Mode or setting STAY
Mode 2 zones.
Flashing once
every 3 sec
Day alarm status – day alarm turned
on.
3.4 System Disarmed
This indicator appears with the
indicator
when the system is disarmed.
3.5 MAINS Indicator
The MAINS indicator appears when the
system’s AC MAINS supply is normal or failed.
Table 4: MAINS Indicator
MAINS Indicator Definition
On AC MAINS power normal.
Flashing AC MAINS supply failed.
3.6 Off Indicator/Zone Sealed
The
indicator appears when the system
is disarmed and flashes when a zone
becomes unsealed when disarmed. The
indicator stops flashing when all zones are
sealed.