EasyManua.ls Logo

Bosch LM024 - Page 24

Bosch LM024
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 | Troubleshooting LM CS Series Heat Pump
LM CS Series Heat Pump8 733 920 847 (2014/01) Subject to change without prior notice
YELLOW "ALERT”
FLASH CODE 6
Open Start Circuit
Current only in run
circuit
1. Run capacitor has failed (may not be bad, verify)
2. Open circuit in compressor start wiring or connections
Check wiring and connectors between supply and the
compressor "S'" terminal
3. Compressor start winding is damaged
Check compressor motor winding resistance
YELLOW "ALERT”
FLASH CODE 7
Open Run Circuit
Current only in start
circuit
1. Open circuit in compressor run wiring or connections
Check wiring and connectors between supply and the
compressor "R” terminal
2. Compressor run winding is damaged
Check compressor motor winding resistance
YELLOW "ALERT"
FLASH CODE 8
Welded Contactor
Compressor always
runs
1. Compressor contactor has failed closed
2. Thermostat demand signal not connected to module
YELLOW "ALERT"
FLASH CODE 9
Low Voltage
Control circuit <
17VAC
1. Control circuit transformer is overloaded
2. Low line voltage (contact utility if voltage at disconnect is low)
Check wiring connections Flash Code number
corresponds to a number of LED flashes, followed by a
pause and then repeated. TRIP and ALERT LEDs flashing
at same time means control circuit voltage is too low for
operation
Comfort Alert Module -Flash Codes
Status LED
Status LED
Description
Status LED Troubleshooting Information Solution