Installation and Maintenance Manual
LV MODEL
8733944336 (2016/09)

Table of Contents

Questions and Answers

  • C
    christopher07Sep 23, 2025
    What causes water hammer in my Bosch LV060 Heat Pump and how to fix it?
    • T
      Troy BakerSep 23, 2025
      If you're experiencing water hammer with your Bosch Heat Pump, the cause may be fast closing valves. In this case, change the valves to a slow-close type.
  • T
    Thomas JenkinsAug 23, 2025
    How to reduce objectionable noise levels from my Bosch LV060 Heat Pump?
    • M
      Matthew ThompsonAug 23, 2025
      If you're experiencing objectionable noise levels from your Bosch Heat Pump, ensure the duct work and grilles are properly sized for unit air flow. If the fan speed setting is too high, consult the blower performance table and reduce fan speed if possible. To address structure borne noise, mount the unit on a vibration pad. Also, install the unit in accordance with the provided instructions and adjust the unit location to prevent it from touching the structure.
  • J
    John WallaceAug 25, 2025
    What to do if my Bosch LV060 Heat Pump compressor isn't running and the fan is on, but I suspect low refrigerant?
    • C
      Christopher JohnsonAug 26, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a low-pressure fault caused by low refrigerant. Check the refrigerant pressure with a gauge set.
  • D
    denise67Aug 27, 2025
    What to do if the compressor of my Bosch Heat Pump doesn't work but the fan runs and there is a freeze fault?
    • J
      John PatelAug 27, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a freeze fault in the water coil caused by no or low water flow. Check the water valves and/or pumps to ensure they are operating correctly. Also, check the water coil for any blockages.
  • B
    Benjamin NealAug 27, 2025
    Why is my Bosch LV060 Heat Pump compressor not running but the fan is, possibly due to high water temperature?
    • T
      Tyler ScottAug 27, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a high-pressure fault caused by high water temperature. Check the water temperature to ensure it is within the appropriate range.
  • E
    Elizabeth TaylorSep 17, 2025
    What to do if the fan is not working on my Bosch Heat Pump with a PSC motor?
    • J
      Joseph WilliamsSep 18, 2025
      If the fan on your Bosch Heat Pump isn't working (PSC motor), first check the supply voltage from the fan relay to the motor and ensure that all motor wires are secure. With the power off, spin the motor shaft; noise, resistance, or uneven motion can indicate motor failure. Also, check for 24 VAC across the fan relay coil and check all wiring connections. If the relay coil is energized but the relay does not pull in, check the resistance across the relay coil; an open circuit indicates a faulty relay.
  • S
    Suzanne RichardsonSep 14, 2025
    What to do if the compressor is not working but the fan runs on my Bosch Heat Pump, and it might be related to a brown out fault?
    • D
      David GarciaSep 14, 2025
      If the compressor of your Bosch Heat Pump isn't working, but the fan is still running, it could be due to a brown out fault. This could be caused by low supply voltage, so check the primary voltage to ensure it is within the limits listed on the unit data plate. Another cause may be an overloaded control circuit; if the control voltage is below 18 V, check accessories connected to the unit and ensure that they do not exceed the VA draw. A bad thermostat connection can also cause this issue, so check that the thermostat wiring is the proper gauge and length, that it is not damaged, and that all connections at the thermostat and heat pump are secure.
  • K
    Kenneth MendozaSep 15, 2025
    What to do if the compressor is not working but the fan runs on my Bosch Heat Pump, and it might be related to thermostat?
    • B
      Brian GriffinSep 16, 2025
      If the compressor of your Bosch Heat Pump isn't working, but the fan is still running, ensure that the thermostat is on and calling for 'Y'. Check the 'Y' connection from the thermostat, ensuring that there is 24 VAC between 'Y' and 'C'. Also, check the wiring to ensure that there is 24 VAC across the contactor coil. Finally, test the contactor with 24VAC (between 'R' and 'C'). Ohm the contactor coil; an open circuit indicates a burned coil.
  • M
    Mrs. Catherine LewisSep 6, 2025
    Why is my Bosch LV060 compressor not running, but the fan is, possibly due to condensate drainage issues?
    • D
      douglas01Sep 6, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a condensate fault caused by poor drainage. Check the condensate pan for a high water level. Check the drain line for blockages, double trapping, or inadequate trapping.
  • A
    Angela ThomasSep 3, 2025
    How to troubleshoot a Bosch Heat Pump with no compressor operation but running fan, possibly due to a bad thermostat connection?
    • M
      Michael CabreraSep 3, 2025
      If the compressor of your Bosch Heat Pump is not working, but the fan is running, it might be due to a brown-out fault caused by a bad thermostat connection. Check that the thermostat wiring is of the proper gauge and length, is undamaged, and that all connections at the thermostat and heat pump are secure.

Summary

Key Symbols and Safety Warnings

Safety Warnings

Critical instructions for installation, servicing, and operation.

Installation - Site Preparation

Step 1- Check Job Site

Procedures for checking the job site before installation.

Step 2- Check Unit

Procedures for inspecting the unit upon receipt.

Installation - Unit Placement

Step 3- Locate the Unit

Instructions for locating the unit for optimal installation.

Installation - Mounting and Ducting

Step 4 Mount The Unit

Guidelines for mounting vertical and horizontal units.

Installation - System Connections

Step 5 Check Duct System

Procedures for checking and preparing the duct system.

Installation - Connections and Wiring

Step 7-Pipe Connections

Guidelines for making water piping connections.

Step 8 Wire Field Power Supply

Instructions for wiring field power supply to the unit.

Unit Controls and ECM Interface

ECM-UPM Controls

Description of the ECM-UPM unit controls and interface board.

Safety Features and Protection

Safety Features Overview

Details of the unit's integrated safety features.

Freeze Protection and Reset

Information on freeze sensors, intelligent reset, and lockout reset.

Pre-Start-Up and Start-Up Procedures

System Checkout

Essential checks before initial unit startup.

Unit Start-Up

Procedure to initiate proper unit startup.

Compressor Operation

Unit Start-Up Modes

Certified Performance Data

Fan Motor Options

Blower Motor Electrical Data

Troubleshooting Common Issues

Operating Data Tables

Waterside Pressure Drop Table

Compressor Characteristics

Unit Check Out Sheet

Bosch LV060 Specifications

General IconGeneral
BrandBosch
ModelLV060
CategoryHeat Pump
LanguageEnglish

Related product manuals