Installation and Maintenance Manual
LV MODEL
8733944336 (2016/09)

Table of Contents

Questions and Answers

  • M
    Morgan ShortSep 23, 2025
    What causes water hammer in my Bosch LV018 and how to fix it?
    • C
      Christopher MccormickSep 23, 2025
      If you're experiencing water hammer with your Bosch Heat Pump, the cause may be fast closing valves. In this case, change the valves to a slow-close type.
  • L
    Larry Clark MDAug 23, 2025
    How to reduce objectionable noise levels from my Bosch Heat Pump?
    • A
      Andrew StewartAug 23, 2025
      If you're experiencing objectionable noise levels from your Bosch Heat Pump, ensure the duct work and grilles are properly sized for unit air flow. If the fan speed setting is too high, consult the blower performance table and reduce fan speed if possible. To address structure borne noise, mount the unit on a vibration pad. Also, install the unit in accordance with the provided instructions and adjust the unit location to prevent it from touching the structure.
  • R
    Ricardo BrownAug 25, 2025
    What to do if my Bosch Heat Pump compressor isn't running and the fan is on, but I suspect low refrigerant?
    • K
      Katherine HarperAug 26, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a low-pressure fault caused by low refrigerant. Check the refrigerant pressure with a gauge set.
  • T
    twallAug 27, 2025
    What to do if the compressor of my Bosch LV018 doesn't work but the fan runs and there is a freeze fault?
    • S
      Susan SmithAug 27, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a freeze fault in the water coil caused by no or low water flow. Check the water valves and/or pumps to ensure they are operating correctly. Also, check the water coil for any blockages.
  • K
    Kathryn FosterAug 27, 2025
    Why is my Bosch Heat Pump compressor not running but the fan is, possibly due to high water temperature?
    • C
      Carla MclaughlinAug 28, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a high-pressure fault caused by high water temperature. Check the water temperature to ensure it is within the appropriate range.
  • D
    Dennis WoodSep 17, 2025
    What to do if the fan is not working on my Bosch LV018 with a PSC motor?
    • P
      Paul WarrenSep 17, 2025
      If the fan on your Bosch Heat Pump isn't working (PSC motor), first check the supply voltage from the fan relay to the motor and ensure that all motor wires are secure. With the power off, spin the motor shaft; noise, resistance, or uneven motion can indicate motor failure. Also, check for 24 VAC across the fan relay coil and check all wiring connections. If the relay coil is energized but the relay does not pull in, check the resistance across the relay coil; an open circuit indicates a faulty relay.
  • S
    Susan GonzalezSep 14, 2025
    What to do if the compressor is not working but the fan runs on my Bosch Heat Pump, and it might be related to a brown out fault?
    • V
      Vincent GonzalezSep 14, 2025
      If the compressor of your Bosch Heat Pump isn't working, but the fan is still running, it could be due to a brown out fault. This could be caused by low supply voltage, so check the primary voltage to ensure it is within the limits listed on the unit data plate. Another cause may be an overloaded control circuit; if the control voltage is below 18 V, check accessories connected to the unit and ensure that they do not exceed the VA draw. A bad thermostat connection can also cause this issue, so check that the thermostat wiring is the proper gauge and length, that it is not damaged, and that all connections at the thermostat and heat pump are secure.
  • M
    Megan GarciaSep 15, 2025
    What to do if the compressor is not working but the fan runs on my Bosch LV018 Heat Pump, and it might be related to thermostat?
    • U
      usmithSep 16, 2025
      If the compressor of your Bosch Heat Pump isn't working, but the fan is still running, ensure that the thermostat is on and calling for 'Y'. Check the 'Y' connection from the thermostat, ensuring that there is 24 VAC between 'Y' and 'C'. Also, check the wiring to ensure that there is 24 VAC across the contactor coil. Finally, test the contactor with 24VAC (between 'R' and 'C'). Ohm the contactor coil; an open circuit indicates a burned coil.
  • Z
    Zachary HendersonSep 6, 2025
    Why is my Bosch LV018 compressor not running, but the fan is, possibly due to condensate drainage issues?
    • W
      William HolmesSep 6, 2025
      If your Bosch Heat Pump's compressor isn't running but the fan is, it could be due to a condensate fault caused by poor drainage. Check the condensate pan for a high water level. Check the drain line for blockages, double trapping, or inadequate trapping.
  • E
    emma55Sep 3, 2025
    How to troubleshoot a Bosch LV018 with no compressor operation but running fan, possibly due to a bad thermostat connection?
    • D
      Donald RodriguezSep 3, 2025
      If the compressor of your Bosch Heat Pump is not working, but the fan is running, it might be due to a brown-out fault caused by a bad thermostat connection. Check that the thermostat wiring is of the proper gauge and length, is undamaged, and that all connections at the thermostat and heat pump are secure.

Summary

Key to Symbols and Safety Warnings

Symbol Definitions

Explains symbols used for warnings, cautions, and important information.

Critical Safety Precautions

Highlights essential safety rules for installation, operation, and maintenance.

Model Nomenclature Guide

Installation Procedures

Pre-Installation Checks and Site Selection

Covers initial site assessment, unit inspection, and location selection before installation.

Start-Up and Operation

Application Considerations and Water Quality

Performance Data and Motor Specifications

Troubleshooting Guide

Compressor and Fan Operation Issues

Addresses common issues like no compressor operation, fan faults, and related error codes.

System Performance and Environmental Faults

Covers troubleshooting for temperature, humidity, and noise issues.

Unit Check Out Sheet

Bosch LV018 Specifications

General IconGeneral
Voltage208/230V
RefrigerantR410A
EER Cooling12.0
Cooling Capacity18000 BTU/h
Heating Capacity18000 BTU/h