38 en | Appendices MIC IP starlight 7000i
2017.09 | 0.12 | F.01U.xxx.xxx Installation Manual Bosch Security Systems
1 Indoor main building 2 Network equipment
3 Connect the ground of the camera
power supply to the building earth
ground.
4 Surge protection
5 Connect the ground of the camera to
the ground of the surge protector.
6 Install Cat5e/Cat6e Ethernet (Shielded
Twisted Pair (STP)) cable. Route cable
through grounded metal conduit.
7 Equipment enclosure 8 Outdoor rated High PoE-compatible
midspan
9 Connect the Bus Bar to the Equipment
Grounding Electrode.
10 Outdoor High PoE-compatible surge
protection to protect indoor
equipment
11 Equipment Grounding Electrode 12 Lightning Rod
13 Down Conductor; refer to NFPA 780,
Class 1 and 2.
14 Install outdoor High PoE-compatible
surge protection as close as possible
to the camera. Connect to the
Equipment Grounding Electrode.
15 Lightning Rod Grounding Electrode

Other manuals for Bosch MIC-7502-Z30W