6 720 817 545 (2016/02) Optiflow
16 | Regulating the gas (only for authorised technicians)
Press the button .
The appliance is now ready for adjustment of the maximum
gas flow.
Open a hot water tap.
Press or until the pressure gauge shows the
value indicated in table 10.
Press for 3 seconds.
The displayed value flashes as a sign of confirmation.
▶Press .
Display will show "L1".
Close the hot water tap.
Press until the display shows "E".
Press the button .
Display will show P1.
The adjustment of the maximum gas flow is completed.
5.3.3 Adjusting the minimum flow (Parameter P2)
Press until the display shows "P2".
Press the button .
Display will show "E".
Press until the display shows "L2".
Press the button .
Open a hot water tap.
The appliance is now ready for adjustment of the minimum
gas flow.
Press or until the pressure gauge shows the
value indicated in table 10.
Press for 3 seconds.
The displayed value flashes as a sign of confirmation.
▶Press .
Display will show "L2".
Close the hot water tap.
Press until the display shows "E".
Press the button .
Display will show "P2".
Simultaneously press the , and for 3
seconds.
Display will show the temperature selected.
Disconnect the pressure gauge from the test points [A] and
[B].
Tighten the shutter screws of the test points [A] and [B].
The adjustment of the minimum gas flow is complete.
5.3.4 Adjusting pressure at the burner (Parameter P0)
Enter the Service menu by pressing and holding down the
, , and buttons simultaneously for 3
seconds.
Display will show "P2".
Press until the display shows "P0".
Press the button .
Open a hot water tap.
With the pressure gauge connected, let the value measured
stabilise.
Press or until the pressure gauge shows the
value indicated in table 10.
If it is not possible to reach the differential
pressure value:
Adjust the pressure in the burner
(section 5.3.4) and repeat the
procedure for adjusting minimum flow.
If it is not possible to reach the differential
pressure value:
Adjust the pressure in the burner
(section 5.3.4) and repeat the
procedure for adjusting minimum flow.
Natural gas H LPG
Øinjector
GWH16
1.7 1.25
GWH20
10 x 2.0
5 x 1.7
10 x 1.5
5 x 1.3
GWH26
2.0 1.55
Dynamic
connection
pressure
(kPa)
GWH16
GWH20
GWH26
1.13 2.75
Burner
pressure
(kPa) - P0
GWH16
GWH20
GWH26
0.12
Differential
pressure of
the burner
MAX (kPa) -
P1
GWH16
0.22 - 0.28 0.25 - 0.32
GWH20
0.21 - 0.26 0.26 - 0.32
GWH26
0.21 - 0.29 0.18 - 0.26
Differential
pressure of
the burner
MIN (kPa) -
P2
GWH16
0.03 - 0.06 0.04 - 0.06
GWH20
0.03 - 0.05 0.05 - 0.07
GWH26
0.02 - 0.05 0.03 - 0.06
Table 10 Pressure of the burner
Burner pressure adjustment is only required
if “L1” and “L2” cannot be achieved
according to table. 10