EasyManua.ls Logo

Bosch PTD 1 - Technical Specifications and Operation; Technical Data; Assembly

Bosch PTD 1
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 | English
2 609 140 909 | (5.7.12) Bosch Power Tools
Technical Data
Assembly
Inserting/Replacing the Battery
Using alkali-manganese or rechargeable batteries is recom-
mended for operation of the measuring tool.
To open the battery lid 5, press on the latch 6 and fold the bat-
tery lid up. Insert the batteries/rechargeable batteries. When
inserting, pay attention to the correct polarity according to
the representation on the inside of the battery lid.
The battery low indicator p indicates when the batteries/
rechargeable batteries become empty:
max. 30 % battery power,
max. 10 % battery power.
When the battery low indicator p flashes, the batteries/
rechargeable batteries must be replaced. Measurements are
no longer possible.
Always replace all batteries/rechargeable batteries at the
same time. Do not use different brands or types of batteries/
rechargeable batteries together.
Thermo detector PTD 1
Article number
3 603 F83 000
Measuring range
Surface temperature
Ambient temperature
Relative humidity
–20...+200 °C
–10...+40 °C
10...90 %
Measuring accuracy (typically)
Surface temperature
1) 2)
–<+10°C
+10...30 °C
+30...90 °C
–>+90°C
Ambient temperature
typically
Relative humidity
2)
–<20%
20...60 %
60...90 %
±C
±C
±C
±5%
±C
±3%
±2%
±3%
Optic (relation of measuring distance : measuring spot)
3) 4)
10 : 1
Operating temperature
–10...+40 °C
Storage temperature
–20...+70 °C
Laser class
2
Laser type (typically)
635 nm, <1 mW
Batteries
Rechargeable batteries
2x1.5VLR06 (AA)
2 x 1.2 V HR06 (AA)
Operating life time, approx.
9h
Weight according to EPTA-Procedure 01/2003
0.3 kg
Dimensions (length x width x height)
124x53x180mm
1) At a measuring distance of 0.751.25 m to the surface
2) At an ambient temperature of 22 °C
3) Information according to VDI/VDE 3511 Page 4.3 (publication date: July 2005); applies for 90 % of the measuring signal.
Deviations of the measuring results are possible in all ranges beyond the indicated dimensions in the Technical Data.
4) Refers to infrared measurement, see graphic:
1,7 cm
10 cm
0,17 m
1 m
OBJ_BUCH-1625-001.book Page 12 Thursday, July 5, 2012 8:56 AM