34/36 Bosch Rexroth AG
Reparaturanleitung/Repair Manual A10VG 28–63
RDE 92750-21-R/02.08
5.4 Checking the Hydraulic Zero Stroke
This section describes how to check the hydraulic zero stroke
for HW, HD, and EP controllers.
WARNING
!
Danger of injuries
The following procedures carried out on the variable pump are
dangerous.
Pay attention to the safety advice (refer to "Safety",
page 7).
Block the machinery or unload the unit before you procede
with the installation.
To check the hydraulic zero stroke:
1 Connect manometers to the ports X1 and X2.
2 Check if both manometers show the same pressure value
when the unit is blocked
Note
Never turn the eccentric calibration (a) of the controller over
±90 degrees.
5.4 Hydraulische Nulllage überprüfen
Dieser Abschnitt erklärt, wie Sie die hydraulische Nulllage bei
HW-, HD- und EP-Steuergeräten überprüfen.
WARNUNG
!
Verletzungsgefahr
Die folgenden Arbeiten an der Verstellpumpe sind gefährlich.
Beachten Sie die Sicherheitshinweise (siehe „Sicherheit“
auf Seite 7).
Blockieren Sie das Fahrzeug bzw. entlasten Sie die Anlage
bevor Sie die Einstellarbeiten durchführen.
HW
HD EP
X1
X2
Messbereich/
Metering range
0 ... 60 bar
Um die hydraulische Nulllage zu überprüfen:
1 Schließen Sie an die Anschlüsse X1 und X2 Manometer an.
2 Überprüfen Sie, ob bei blockiertem Antrieb beide Manometer
den gleichen Druckwert anzeigen.
Hinweis
Verdrehen Sie die Exzenterjustierung (a) am Steuergerät nicht
über ±90°.