6.2.2 Viewing customer service program
Customer Service Program
Step
Displayed
step
Action
Can advance
step
Time Temperature
Water
amount Remarks
0 0 Check Coil no -- Checks pumps and other components
(when switched on)
1 0 Drain Pump 15s Drain pump O
K
2 1,2 Filling partly 72s 3.0 L Checks if water level above filter level
3 3,4 Pause yes 10s Checks water level
4 5,6,10,11 Drain Pump yes 20s empty Sump base completely empty
5 12,13,14 Filling + Main Pump no 96s 4.0 L Checks if water level at top of coarse filter -
main pump starts at displayed step 13
6 15 Main Pump + Soap
Dispense
r
yes 10s
7 16 Main Pump + Aqua
Sensor Calibration
partly 110s
8 17 Main Pump + Heating 104°F
918Pause yes 5s
10 19 Main Pump yes 5s Start main pump
11 20 Main Pump + Rinse
A
gent + Heating
yes 60s # of dispenser coil impulses = rinse agent
setting
12 21 Main Pump + Heating yes 149° F
A
bout 2.5°F/min
13 22 Main Pump yes 15s
14 24 Drain Pump no -- Displays "0" when done
Hint
: If a failure occurs the program goes on, stops or ends according to the failure handling.
Remark: Filling can not be stepped over