Not Used Assign this to zones that you do not intend to use, so that they
are removed from the system.
Each zone has a unique location that specifies its zone type. In order to select one of
the above zone types for a specific zone, you will need to enter its corresponding
number into the zone type location for that zone:
0 = Instant
1 = Handover
2 = Delay-1
9 = 24hr Tamper
15 = Not Used
These are the locations for the zone types for all zones (including default zone types):󳆬
Zone 1 = 267 (default = 2 Delay-1)
Zone 2 = 274 (default = 1 Handover)
Zone 3 = 281 (default = 1 Handover)
Zone 4 = 288 (default = 1 Handover)
Zone 5 = 295 (default = 0 Instant)
Zone 6 = 302 (default = 0 Instant)
Zone 7 = 309 (default = 0 Instant)
Zone 8 = 316 (default = 9 24-Hour Tamper)
Zone 9 = 323 (default = 15 Not Used)
Zone 10 = 330 (default = 15 Not Used)
Zone 11 = 337 (default = 15 Not Used)
Zone 12 = 344 (default = 15 Not Used)
Zone 13 = 351 (default = 15 Not Used)
Zone 14 = 358 (default = 15 Not Used)
Zone 15 = 365 (default = 15 Not Used)
Zone 16 = 372 (default = 15 Not Used)
The following example will show you how to set up a standard system with Zone 1 as an
entry delay, Zone 2 as a “handover”, Zone 3 as an “instant”, Zones 4 - 8 as “not used”,
and Zone 16 as your tampers (Solution 3000):
1. Enter the text menu: [ 1 2 3 4 # ]
2. Enter address program: [ 8 1 ]
3. By default, Zone 1 is already set as Delay-1, so we can leave it.
4. By default, Zone 2 is already set as a Handover, so we can leave it.
Page !4 of !12

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)

Related product manuals