5. Go to the location of the zone type for Zone 3: [ 2 8 1 # ]
6. Change the 1 (Handover) to a 0 (Instant): [ 0 * ]
7. Go to the location of the zone type for Zone 4: [ 2 8 8 # ]
8. Change the 1 (Handover) to a 15 (Not Used): [ 1 5 * ]
9. Go to the location of the zone type for Zone 5: [ 2 9 5 # ]
10. Change the 0 (Instant) to a 15 (Not Used): [ 1 5 * ]
11. Go to the location of the zone type for Zone 6: [ 3 0 2 # ]
12. Change the 0 (Instant) to a 15 (Not Used): [ 1 5 * ]
13. Go to the location of the zone type for Zone 7: [ 3 0 9 # ]
14. Change the 0 (Instant) to a 15 (Not Used): [ 1 5 * ]
15. Go to the location of the zone type for Zone 8: [ 3 1 6 # ]
16. Change the 9 (24-Hour Tamper) to a 15 (Not Used): [ 1 5 * ]
17. Zones 9 - 15 are set as “Not Used” by default, so can be left as they are.
18. Go to the location of the zone type for Zone 16: [ 3 7 2 # ]
19. Change the 15 (Not Used) to either a 9 or 0: [ 9 * ] or [ 0 * ]
20. Save and exit programming mode: [ 9 6 0 # ]
To further elaborate, using Zone 3 as an example:
1. We went to the location of the zone type for Zone 3: [ 2 8 1 # ]. The number 1 was in
that location, indicating that the zone type for Zone 3 was a handover.
2. We changed the 1 (Handover) to a 0 (Instant): [ 0 * ]
Using the above information, make the necessary programming changes to your system. If
you are using a Solution 2000, only zones 1 - 8 can be used, so you should use Zone 8 as
your tamper zone, which is already a 24-hour tamper by default.
III. Handover Delay Sequential
If you have zones with a handover zone type, those handover zones must be triggered
in order (i.e., Zone 2, Zone 3, etc.) following a delay zone in order to carry on its entry
time, otherwise an alarm will activate. If you require a system with handover zones that
may be triggered out of order following a delay zone (e.g., Zone 3, Zone 2), then you
may choose handover delay to be non-sequential:
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location for System Options 3: [ 4 9 4 # ]
3. Change the 8 to a 0: [ 0 * ]
4. Save and exit: [ 9 6 0 # ]
Options
Page !5 of !12

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)

Related product manuals