EasyManuals Logo

Bosch Solution 2000 Programming

Bosch Solution 2000
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Combining the time of 8 seconds in location 470 with the time of 112 seconds specified in
location 471 will give a total exit time of 120 seconds.
VI. Set Stay Mode 1
Stay Mode 1 can be used to have the system partially armed with some zones isolated,
whilst others remain active. This is ideal if you still want some zones armed whilst you are
at home, especially at night when you are sleeping, e.g., doors, windows, bottom storey,
back rooms, shed, garage zones unlikely to be entered by household members.
You can specify which zones are to be isolated in Stay Mode 1 by selecting the option
“Isolated in Stay Mode 1” in Zone Options 2 for the required zone. Each zone stores its
Zone Options 2 information at a unique location.
These are the locations for Zone Options 2 for each zone:
Zone 1 = 271
Zone 9 = 327
Zone 2 = 278
Zone 10 = 334
Zone 3 = 285
Zone 11 = 341
Zone 4 = 292
Zone 12 = 348
Zone 5 = 299
Zone 13
= 355
Zone 6 = 306
Zone 14
= 362
Zone 7 = 313
Zone 15
= 369
Zone 8 = 320
Zone 16
= 376󳆬
To select a zone for isolation in Stay Mode 1, you must enter a 15 at its location for Zone
Options 2.
For example, to have Zone 5 isolated in Stay Mode 1:
1. Enter programming mode: [ 1 2 3 4 # ]
2. Go to the location of Zone Options 2 for Zone 5: [ 2 9 9 # ]
3. Change the 14 to a 15: [ 1 5 * ]
4. Save and exit: [ 9 6 0 # ]
You can arm the alarm system in Stay Mode 1 by either holding down the [ * STAY ]
button for three seconds, or by entering your user code and pressing [ * STAY ], e.g., [
2 5 8 0 * ]. The isolated zones will flash on the keypad and the Stay (person inside
house) indicator will display.
VII. Change Installer Code
Each number of the installer code is stored in its own location. There are four locations:
Page !7 of !12

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)