Test Program (2C): Motor Control
Test Program (2C): Motor Control
Fault Codes (Test 1)
Fault Codes (Test 1)
Test P1:ERRORS / P:01 (Viewing motor control fault codes) -- Start & end test P1 by
pushing Start/Pause button. Scroll through all fault codes by pushing Spin Selection (WFMC32/33/53) or
Menu (WFMC64/84) buttons. If motor fault codes can’t be accessed, no faults occurred control module
fault codes will show repeatedly.
WFMC32/33/53 displays alternates between fault code (e.g. d:01) & when fault occurred on in last 16
washes (e.g. C:00) – shows C:00 if fault didn’t occur.
WFMC64/84 displays show fault code & when fault occurred in last 16 washes (e.g. 0 - dr:01).
WFMC32/WFXD52
Displays
WFMC64/WFXD84
Displays
Test # Problem Possible Cause
(
s
)
d:01 dr:01 P:04
Motor control short circuited. Faulty motor control.
d:02 dr:02 P:04
Motor control interruption. Faulty motor control.
d:03 dr:03 P:04
Damaged motor control temperature sensor. Faulty temperature sensor.
d:06 dr:06 P:04
NTC relay failure. NTC too hot or relay stuck closed.
d:07 dr:07 P:04
Motor control (inverter) failed or motor shorted. Faulty motor control or motor.
d:08 dr:08 P:04
Motor speed sensor failed. Faulty speed sensor or wire harness.
d:09 dr:09 P:04
Voltage too high. Faulty motor control.
d:10 dr:10 P:04
Power limiter switch off. Motor overloaded or binding.
d:11 dr:11 P:04
Voltage too low. Faulty motor control.
d:12 dr:12 P:04
Motor control high current switch off. Motor overloaded or binding.
d:13 dr:13 P:04
Motor control high temperature switch off. Motor overloaded or binding.
d:14 dr:14 P:04
Motor control high temperature warning. Motor overloaded or binding.
d:15 dr:15 P:04
Power limiter warning. Motor overloaded or binding.
d:16 dr:16 P:04
Motor high temperature switch off. Motor overloaded or binding.
d:17 dr:17 P:04
Motor high temperature warning. Motor overloaded or binding.
d:18 dr:18 P:04
Peak voltage too high. Faulty motor control.
Last 16 fault codes are
stored & displayed!
HINT: Motor fault codes don’t
show if none occurred -- # of
faults reads “0 for faults which
didn’t occur. Scroll thru all
faults and look at # of faults to
see which faults occurred.
NOTE
: Fault codes stored in
motor control can’t
be cleared .
HINT
: If no motor fault codes occurred, fault codes can’t be
scrolled to – module fault codes will show up repeatedly.