Transportation, storage and disposal en
45
18.1 Emergency release
Releasing the door
Requirement:The drain pump is
empty. →Page35
1. ATTENTION! Escaping water may
cause material damage.
Do not open the door if you can
see water through the glass.
Pull the emergency release down-
wards with a tool and release.
a The door lock is released.
2. Insert the maintenance flap and
lock it into place.
3. Close the maintenance flap.
Transportation, storage and disposal
19 Transportation, stor-
age and disposal
Transportation, storage and disposal
19.1 Removing the appliance
1. Turn off the tap.
2. Empty the water inlet hose.
3. Switch off the appliance.
→"Switching off the appliance",
Page32
4. Unplug the appliance's mains plug.
5. Drain the water.
→"Cleaning the drain pump",
Page35
6. Detach the hoses.
19.2 Inserting the transit
bolts
Secure the appliance before trans-
portation using transit bolts in order
to prevent transport damage.
1. Use a screwdriver to remove the 4
cover caps.
Keep the cover caps.
2. Insert the 4 transit bolts.
→"Removing the transit bolts",
Page14
19.3 Using the appliance
again
For further information, see
→"Installation and connection",
Page13 and
→"Starting an empty washing
cycle", Page17.