6
CLEARANCES
Your installer will
have provided adequate
space around the appliance
for safety and servicing. Do
not restrict this space by
the addition of cupboards,
shelves etc. close to the
appliance.
Minimum clearances in millimetres.
ROOM THERMOSTAT
A room thermostat may be fitted for control of the central heat-
ing temperature. It will be located in one room of the home. The
method of setting a room thermostat varies with the type and manu-
facture. Refer to the instructions supplied with the room thermostat.
THERMOSTATIC RADIATOR VALVES
If thermostatic radiator valves are fitted to the system then they
must conform to the requirements of BS2767. The radiator located in
the room where the room thermostat is sited must be controlled by a
thermostatic radiator valve.
VENTILATION OF ROOM SEALED FANNED
FLUE (RSF) APPLIANCES
These are room sealed appliances and any ventilation openings
in a wall or door must not be obstructed. Do not allow the flue termi-
nal fitted on the outside wall to become obstructed or damaged.
NOTE: Do not place anything on top of the appliance. If the
appliance is fitted in a compartment do not use the compartment for
storage purposes unless it conforms to the requirements of
BS 6798:1987: Section 6. It is essential that the airing space is separat-
ed from the boiler space by a perforated non-combustible partition as
described in BS 6798:1987.
CIRCULATING PUMP
This may be fitted with a speed adjuster. If so it will be factory
set at maximum and should be adjusted by the installer to suit the
heating load.
15SBi 24SBi
Left-hand side 10 10
Right-hand side 10 10
In Front 600 600
Above 180 180
Below 200 200