EasyManua.ls Logo

Bosch Worcester Greenstar CDi Compact ErP Series - Page 20

Bosch Worcester Greenstar CDi Compact ErP Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PRE-INSTALLATION
CDi Compact
ErP
- 6 720 813 276 (2015/07)20
High level horizontal flue
High level horizontal flue with additional elbows
High level horizontal flue with additional elbows
Vertical balanced flue assembly
Vertical balanced flue with elbow offset (2 x 90 ° bends)
Vertical balanced flue with elbow offset (2 x 45 ° bends)
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue 6,000 15,000
Table 16
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 2 x 90° bends 4,000 13,000
Table 17
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 3 x 90° bends 2,000 11,000
Table 18
6720806945-22.1Wo
6720806945-23.1Wo
6720806945-24.1Wo
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue assembly 6,000 15,000
Table 19
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 90° bends 2,000 11,000
Table 20
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 45° bends 4,000 13,000
Table 21
6720806945-25.1Wo
A = 300 mm
B = 500 mm
6720806945-26.1Wo
6720806945-27.1Wo

Table of Contents