PRE-INSTALLATION
CDi Compact
ErP
- 6 720 813 276 (2015/07)20
High level horizontal flue
High level horizontal flue with additional elbows
High level horizontal flue with additional elbows
Vertical balanced flue assembly
Vertical balanced flue with elbow offset (2 x 90 ° bends)
Vertical balanced flue with elbow offset (2 x 45 ° bends)
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue 6,000 15,000
Table 16
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 2 x 90° bends 4,000 13,000
Table 17
Maximum flue length
(mm)
60/100 80/125
High level horizontal flue with 3 x 90° bends 2,000 11,000
Table 18
6720806945-22.1Wo
6720806945-24.1Wo
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue assembly 6,000 15,000
Table 19
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 90° bends 2,000 11,000
Table 20
Maximum flue length
(mm)
60/100 80/125
Vertical balanced flue with 2 x 45° bends 4,000 13,000
Table 21
6720806945-25.1Wo
A = 300 mm
B = 500 mm
6720806945-26.1Wo
6720806945-27.1Wo