COMMISSIONING
CDi Compact
ErP
- 6 720 813 276 (2015/07) 35
6.4 Starting the appliance
Fig. 54 Control panel
Switching the appliance on/off:
▶ Turn on the mains power supply, initially the “Boiler start up screens”
will be displayed (refer to figure 55).
▶ Turn on any external controls
▶ Set the thermostatic radiator controls to maximum temperature
▶ Set the clock/programmer to continuously ON and the room
thermostat to maximum temperature
The blue Operation and fault indicator light will be illuminated when
there is a demand for heat or hot water.
Turn the boiler CH temperature control (6) to maximum.
The “burner on” flame symbol will be shown on the boiler display after a
successful ignition sequence.
If the boiler fails to light, a flashing fault code will be displayed.
To reset the boiler, press the reset button (4), the tick symbol will be
displayed briefly for a successful reset.
CAUTION: RUNNING THE APPLIANCE
▶ Never run the appliance when the appliance/system is empty or partially filled.
6720643358-02.1Wo
1 3 65 7 8 9 10 11 12 13 1442
Key to figure 54
1 Spanner/return button
2 Service engineer symbol
3 Eco button
4 Reset button
5 Boiler display
6 Central heating temperature control
7 Scroll up button
8 OK - Select/confirmation button
9 Scroll down button
10 Operation and fault indicator (blue)
11 Position for optional programmer
12 Hot water temperature control
13 Diagnostic port
14 System pressure gauge
NOTICE: RESET
▶ Do not press the blue operation/fault diagnostic
indicator (10) to reset the boiler.