Electrical connection
Condens 5000W – 6720813952 (2019/02)
16
Use as a guide only. Refer to AS/NZS5601 or local gas fitting rules for
specific locations.
Fig. 23 Flue terminal positions
[I] Mechanic air inlet
[M] Gas meter
[P] Electricity meter or fuse box
[T] Flue terminal
[W] Window
[ ] Shaded area indicates prohibited area
Table 7 Minimum clearances
6 Electrical connection
When establishing the electrical connections, also observe the
documentation and wiring diagram of the accessory being connected
( chapter 2.12).
CAUTION:
Risk of electric shock.
Always isolate the wall mounted gas condensing boiler from the
power supply before working on the electrical parts.
NOTICE:
Short circuit.
Only use original cables if they must be replaced.
In order to commission and shut down the wall mounted gas condensing
boiler, the mains plug and therefore the socket (230 V AC, 50 Hz) must
be accessible at all times. The socket must be earthed (earthing
contact).
Use a 2-wire power cable with 0.4 - 0.8 mm
2
cross-section for all 24 V
AC connections on the terminal strip.
6.1 Control principle
The wall mounted gas condensing boiler is suitable for control according
to the principles of room temperature-dependent and weather-
dependent control.
In the case of room temperature-dependent control, the user
interface in 1 room controls the temperature required within it (room
temperature-dependent controller). In order to control the
temperature correctly, radiators must be equipped with manual
radiator valves or the thermostatically controlled radiator valves
must be fully open ( figure 24).
With weather-dependent control, the temperature in all rooms is
controlled by thermostatically controlled valves mounted on the
radiators. The controls can be installed in any location ( figure 25).
Fig. 24 Control principle of room temperature-dependent control
[1] Wall mounted gas condensing boiler
[2] Room temperature-dependent controller
[3] Radiator valve
[4] Thermostatically controlled radiator valve
[5] Other rooms
[6] Living space
[7] Installation location
Fig. 25 Principle of weather-compensated control
[1] Wall mounted gas condensing boiler
[2] Room temperature-dependent controller
[3] Thermostatically controlled radiator valve
Ref. Item Min.
clearances
[mm]
a Below eaves, balconies and other projections
(Appliances over 50Mj/h)
300
b From the ground, above a balcony or other surface 300
c From a return wall or external corner 300
d From a gas meter 1,000
e from an electricity meter or fusebox/breaker panel 500
f From a drain pipe or soil pipe 75
g Horizontally from any building structure or
obstruction facing a flue terminal
500
h From any other flue terminal, cowl or combustion
air intake
300
j Horizontally from any opening window, non-
mechanical air inlet or other opening into a building
with the exception of sub-floor ventilation
1,500
k From a mechanical air inlet including a spa blower 1,000
n Vertically below an opening window, door, non-
mechanical air inlet or other opening into a building
with the exception of sub-floor ventilation
1,500
0010024745-001
0010010002-001
1
2
7
6
5
4
3
0010010003-001
1
2
6
7
5 4
3
3
8