Operating the appliance
21
Condens 5000W – 6720813952 (2019/02)
Table 10 Setup menu
7.3 Flue gas inspector mode
DHW mode is not possible in flue gas inspector mode. Flue gas inspector
mode terminates automatically after 30 minutes. Settings that have
been changed in flue gas inspector mode are cancelled.
You can put the wall mounted gas condensing boiler into heating mode
when in flue gas inspector mode in order to carry out measurements.
Make sure that the wall mounted gas condensing boiler can release its
heat.
Press key d for 5 seconds to activate flue gas inspector mode.
The gas inspector symbol C [1] appears in the display. Flue gas
inspector mode now remains active with 100% output for
30 minutes.
Set the required output (in %) [3] via the keys M and N.
Perform the required measurement.
Hold down d to switch off the flue gas inspector mode.
Fig. 39 Display in flue gas inspector mode
7.4 „Fault history“ menu
This menu shows the last 3 interlocking fault displays in the form of fault
codes.
Hold down L for 5 seconds to open the “Fault history” menu.
Press M or N to display the last 3 fault messages. The fault displays are
chronologically identified with “Log1” to “Log3”. For further details on
the meaning of fault codes see chapter 12).
Press L to exit the “Fault history” menu and return to the start
screen.
Fig. 40 Fault history
7.5 Key lock
The setup menu can be locked to prevent the settings from being
changed by unauthorised personnel. Proceed as follows:
Activation
Press the M and N keys simultaneously for 5 seconds. The word
“Lock” is displayed for 5 seconds. The information menu remains
readable.
Fig. 41 Display - Lock
Disable
Press the L and c keys again simultaneously for 5 seconds to
remove the key block; the word “Lock” disappears.
Set the maximum boiler temperature
based on the heating system type.
Adjustment range: 30 - 90 °C.
Examples of settings:
40 °C underfloor heating system
75 - 85 °C radiators
85 - 90 °C convectors
Set the maximum output of the heating
system.
The output is displayed in % when modifying
the setting.
Adjustment range: 0 - 100%.
No information about DHW mode is shown
here.
Change the minimum pump speed if
required.
Adjustment range:
30 % - max. (setting max. parameter).
Increase the minimum pump speed if
parts of the heating system do not
become hot enough.
Change the maximum pump speed if
required.
Adjustment range:
min. (setting min. parameter):
Type 70 - 65%
Type 100 - 83%
Reduce the maximum pump speed if
aggravating flow noises can be heard.
Run-on time of the pump following expiry of
heating mode [Min].
Adjustment range: 1 - 60 min./24 hours.
Setup menu
0010020133-001
3
2
1
0010020134-001
10011620-001