Product Information
5
Condens 5000W – 6720813952 (2019/02)
2.4 Scope of delivery
The wall mounted condensing boiler is supplied ex works ready
assembled.
Check that the delivery is complete and undamaged.
Fig. 1 Scope of delivery
[1] Wall mounted gas condensing boiler
[2] Mounting bracket
[3] Technical documentation
[4] Condensate trap
[5] Condensate hose
[6] Screw, washer, rawl plug (2 × )
[7] Screw fitting with gasket (2 × )
[8] Strain relief (6 × )
2.5 Changing over the gas type
This appliance is only certified for use with Natural Gas in AU/NZ, and is
approved for the gas type specified on the data plate. If the wall mounted
gas condensing boiler can be converted for another gas type,
corresponding information will be provided in the gas data
( chapter 2.14, page 10).
2.6 Accessories
A wide range of accessories is available for these wall mounted gas
condensing boilers. Please contact the manufacturer for further details.
You will find the relevant addresses on the back cover of these
instructions.
2.7 Removing the casing
Undo locking screws [1.].
Pull the 2 click fasteners on the underside of the control panel down
[2.].
Remove the casing [3.].
Fig. 2 Casing removal
2.8 Anti-Freeze Protection
NOTICE:
System damage.
The central heating system may freeze up during severe frost due to: the
failure of the electricity supply, inadequate gas supply or an appliance
error.
Install the boiler in a frost-free room.
Drain off the water from the central heating system if it will be out of
operation for an extended period.
The wall mounted gas condensing boiler is equipped with integral frost
protection. This means that the wall mounted gas condensing boiler
requires no external frost protection system. The frost protection system
switches the wall mounted gas condensing boiler off at a boiler
temperature of 7 °C and a boiler temperature of 15 °C. The wall mounted
gas condensing boiler does not protect the heating system from frost.