Information about the appliance | 21
6 720 806 992 (2015/03)Greenstar
3.14 Technical data heating boiler ZBR35-3A...
Input/Output Unit NG LPG (propane)
Max. input rate 180/79 °F (82/26 °C) BTU/hr (kW) 131,900 (38.6) 129,100 (37.8)
Max. output rate 104/86 °F (40/30 °C) BTU/hr (kW) 122,800 (36.0) 122,800 (36.0)
Max. output rate 122/86 °F (50/30 °C) BTU/hr (kW) 121,800 (35.7) 121,800 (35.7)
Max. output rate 176/140 °F (80/60 °C) BTU/hr (kW) 116,700 (34.2) 116,700 (34.2)
Min. input rate 180/79 °F (82/26 °C) BTU/hr (kW) 36,000 (10.5) 46,400 (13.6)
Min. output rate 104/86 °F (40/30 °C) BTU/hr (kW) 35,100 (10.3) 46,100 (13.5)
Min. output rate 122/86 °F (50/30 °C) BTU/hr (kW) 34,800 (10.2) 45,700 (13.4)
Min. output rate 176/140 °F (80/60 °C) BTU/hr (kW) 31,700 (9.3) 42,000 (12.3)
Gas connection value
Natural Gas – H
s
= 1,010 BTU/ft
3
(37.3MJ/m
3
)ft
3
/hr (m
3
/h) 130 (3.7)
Liquid Propane Gas – HD-S = 2,500 BTU/ft3 (93.1MJ/m3) ft
3
/hr (m
3
/h) 52 (1.5)
Permissible inlet gas pressure
NG in. W.C. (mbar) 3.5-10.5" (8.7-26.1)
LPG (propane) in. W.C. (mbar) 8-13" (19.9-32.3)
Flue gas
Flue gas mass flow at maximum/minimum nominal output gps 15.7/4.5 15.2/5.6
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum nominal
heat input
°F ( °C) 162/135 (72/57) 162/135 (72/57)
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum nominal
heat input
°F ( °C) 127/91 (53/33) 127/91 (53/33)
CO
2
at max. nominal output % 9.4 11.0
CO
2
at minimum nominal output % 8.6 10.4
Condensate
Max. condensate quantity (t
R
= 86 °F (30 °C)) gph (l/h) 0.8 (3.1) 0.8 (3.1)
pH level, approx. 4.8 4.8
General
Voltage VAC 120 120
Frequency Hz 60 60
Max. power consumption (central heating mode) W 205 205
Max. power consumption (Stand-by) W < 6 < 6
Sound pressure level
dB(A)
44 44
Max. supply temperature °F ( °C) 190 (88) 190 (88)
Max. permissible operating pressure (P
MS
) heating psi (bar) 30 (2.07) 30 (2.07)
Permissible ambient temperature °F ( °C) 32 - 122 (0 - 50) 32 - 122 (0 - 50)
Nominal water capacity (heating) Gal (L) 0.925 (3.5) 0.925 (3.5)
Weight (without packaging) lbs. (kg) 103.6 (47) 103.6 (47)
Dimensions, W x H x D inch
(mm)
17-21/64" × 33-15/32" × 13-57/64"
(440 × 850 × 353)
Table 6 Technical data heating boiler ZBR35-3A...