EasyManua.ls Logo

Bosch ZBR16-3A Series - Vent and Combustion Air Pipe Lengths

Bosch ZBR16-3A Series
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 | Installation
Greenstar6 720 806 992 (2015/03)
Fig. 39 Vertical venting system (sealed combustion)
[1] Intake
[2] Exhaust
X Greater than 12 inches (305 mm)
Y 12 inches (305 mm) above maximum snow level or at least
24 inches (610 mm) whichever is greater
Fig. 40 PolyPro Flex Chimney Cap (PP) vertical venting system (sealed
combustion)
[1] Intake
[2] Exhaust
Fig. 41 Horizontal venting system (telescopic concentric vent kit)
6.8.3 Vent and combustion air pipe lengths
3" (76 mm) Vent and combustion air pipe
For all installation situations and for all appliances the maximum vent
and combustion air pipe length is 100 feet each, with no more than
8 elbows each.
2" (50 mm) Vent and combustion air pipe
The maximum combined vent and combustion air pipe length
( tab. 20, 21 and 22) depend on the installation situation, the
appliance type and the number of elbows used.
2
6 720 641 933-08.1O
Y
X
1
Y
X
X
6 720 806 922-08.2O
1 2
With Flex Pipe the maximum length is reduced by 50%.
Flex Pipe according to the suppliers instructions for use
in the vertical part of the installation only.
Installations Fig. 32, 33, 34, 36, 37 and 39
Separate terminations
2" PIPE Maximum straight vent pipe length allowed
for Ø 2" pipe
Number of 90 °
elbows used
ZBR16-3A
ZBR21-3A
ZBR28-3A
ZWB28-3A
ZBR35-3A
ZWB35-3A
ZBR42-3A
ZWB42-3A
1 81 ft (24.6 m) 65 ft (19.8 m)
2 76 ft (23.1 m) 57 ft (17.3 m)
3 71 ft (21.6 m) 48 ft (14.6 m)
4 66 ft (20.1 m) 40 ft (12.2 m)
5 61 ft (18.6 m) 32 ft (9.8 m)
6 56 ft (17.1 m) 23 ft (7.0 m)
Table 20 Vent and combustion air pipe lengths with 2" diameter and
separate terminations
1/4" per foot
(50 mm per meter)
6 720 641 933
-
78.1O

Table of Contents