EasyManua.ls Logo

Bose Professional PowerShare PS604A - 4-Channel Configuration; Technical Information; LED Fault Indication

Bose Professional PowerShare PS604A
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
pro.Bose.com
24 English Installation Guide
POWER LED (both amplifiers)
Solid amber LED indicates an over-temperature fault
Solid red LED indicates a power supply fault
SIGNAL LED (both amplifiers)
All four LEDs will display solid red if a power supply fault is detected
LIMIT LED (both amplifiers)
Each LIMIT LED will individually display solid red if there is an EHF fault on that channel
LIMIT LED 1 & 2 will display solid red when the outputs are muted due to an amplifier one fault
LIMIT LED 3 & 4 will display solid red when the outputs are muted due to an amplifier two fault
All four LEDs will display solid red if there is a power supply fault
LED Fault Indications
Adaptable Power Amplier
LIMIT
SIGNAL
12 3 4
PowerShare
POWER
Figure 9. PS604A and PS404A
4-Channel Configuration
Figure 8. PowerShare Editor software 4-channel configuration for PS604A and PS404A amplifiers

Related product manuals