Simplified Load and Pitch Limit Charts pro.Bose.com
Page 14 Installation and Safety Guidelines
Large Array Frame with Short Extender Bars (In Position): 6 Modules
6-Module (60° Total V) 6-Module (70° Total V) 6-Module (75° Total V)
Array Desired Pickup Predicted Array Desired Pickup Predicted Array Desired Pickup Predicted
Modules Pitch Point Pitch Modules Pitch Point Pitch Modules Pitch Point Pitch
RMxx05
10 17 10.3
RMxx05
10 17 10.7
RMxx05
10 20 10.4
RMxx05
5 23 5.0
RMxx05
5 23 5.5
RMxx10
5 26 5.0
RMxx10
0 28 0.6
RMxx10
0 29 0.1
RMxx10
0 31 0.5
RMxx10
-5 32 -2.9
RMxx10
-5 32 -2.6
RMxx10
-5 34 -4.9
RMxx10
-10 37 -9.9
RMxx20
-10 37 -9.6
RMxx20
-10 39 -9.4
RMxx20
-15 n/a* n/a*
RMxx20
-15 n/a* n/a*
RMxx20
-15 n/a* n/a*
-20 n/a* n/a* -20 n/a* n/a* -20 n/a* n/a*
-25 n/a* n/a* -25 n/a* n/a* -25 n/a* n/a*
6-Module (80° Total V) 6-Module (85° Total V) 6-Module (90° Total V)
Array Desired Pickup Predicted Array Desired Pickup Predicted Array Desired Pickup Predicted
Modules Pitch Point Pitch Modules Pitch Point Pitch Modules Pitch Point Pitch
RMxx05
10 19 10.3
RMxx05
10 16 10.2
RMxx05
10 17 10.8
RMxx05
5 24 5.8
RMxx05
5 22 5.0
RMxx05
5 23 5.5
RMxx10
0 30 0.4
RMxx05
0 27 0.6
RMxx10
0 29 0.2
RMxx20
-5 32 -1.5
RMxx10
-5 32 -3.8
RMxx10
-5 32 -2.5
RMxx20
-10 38 -9.5
RMxx20
-10 36 -9.8
RMxx20
-10 37 -9.6
RMxx20
-15 n/a* n/a*
RMxx40
-15 n/a* n/a*
RMxx40
-15 n/a* n/a*
-20 n/a* n/a* -20 n/a* n/a* -20 n/a* n/a*
-25 n/a* n/a* -25 n/a* n/a* -25 n/a* n/a*
Simplified Chart Notes:
1) Modeler
®
software calculates “array pitch” referenced to the acoustic centerline axis of the module in the first (top most) array
position. To convert the Modeler
®
array pitch number to the “array frame” pitch used in the above tables, take the Modeler
®
array
pitch number then add to this number one-half of the nominal coverage angle number of the module in the first array position.
See Figure 10.
2) n/a denotes that array frame pickup point is at maximum; additional pitch requires pull-back bracket with third attachment point.
3) n/a* denotes that WLL limits require use of pull-back bracket to reduce moment force loads; desired pitch may be possible using
additional pickup points of Extender Bars; please consult your local Bose Professional Systems Division Field Engineer or Technical
Support Specialist for additional information.
Figure 10. Modeler
®
Array Pitch versus Array Frame Pitch