There are two relays, A & B, on the bottom of the ELITE Tester. Each relay
has 3 inputs; Normally Open (NO), Common (C), and Normally Closed
(NC). How you wire to your ELITE depends on the type of switch on your
external device. Once you have determined the type of switch, follow the
illustration for connection procedure.
A is triggered on an entry event (passing test result), acting as a switch to
control outside gates, such as doors, light towers, and turnstiles upon a
passing test result.
B is commonly used for exiting, when access is controlled by the ELITE
Test System. It works in conjunction with external I/O devices connected to
the tester such as ID readers and IR exit switches.
B can also be set to mirror Relay A and switch a second device upon an
entry event.
CONNECT
TO
YOUR
RELAYS
P15