22
P12 /P15 /P18
5. Settings and Optimum Operating Values 5.
Machine
P12
P15
Distillation:
Cooling water regulator condenser °C(°F) 45(113)
45(113)
Thermal sensor:
Cycle distillation OFF °C(°F) 135(275)
135(275)
Still stripping OFF °C(°F) 138(280)
138(280)
Still stripping OFF (electric) °C(°F) 145(293)
145(293)
Thermal sensor, distilled solvent °C(°F) 55(131)
55(131)
Panel in steam feeder mm(in) 4(0.16)
4(0.16)
Panel in direct steam line mm(in) 3(0.12)
3(0.12)
Water filling capacity in heating chamber, approx. l(US gal) 5(1.3)
5(1.3)
Pressure control switch, still (el):
ON bar(psi) 5.2(75.4)
5.2(75.4)
OFF bar(psi) 5.6(81.2)
5.6(81.2)
Safety thermostat, heating rod (elec. only) °C(°F) 230(446)
230(446)