24
P12 /P15 /P18
5. Settings and Optimum Operating Values 5.
Machine
P18
Distillation:
Cooling water regulator condenser °C(°F) 45(113)
Thermal sensor:
Cycle distillation OFF °C(°F) 135(275)
Still stripping OFF °C(°F) 138(280)
Still stripping OFF (electric) °C(°F) 145(293)
Thermal sensor, distilled solvent °C(°F) 55(131)
Panel in steam feeder mm(in) 4(0.16)
Panel in direct steam line mm(in) 3(0.12)
Water filling capacity in heating chamber, approx. l(US gal) 5(1.3)
Pressure control switch, still (el):
ON bar(psi) 5.2(75.4)
OFF bar(psi) 5.6(81.2)
Safety thermostat, heating rod (elec. only) °C(°F) 230(446)