23
XMS user guide
Warnings
Bowens.co.uk
Warning and Error Management

operation. If the display shows a Warning or an Error code and it does not automatically
clear itself in a reasonable time then switch the unit to standby and back on again to see
if it then clears.
Warnings: are normally only given because of transient problems. These normally reset
automatically either shortly after the warning or after a period in the case of overheat.
Warnings
DISPLAY
OH
nF
nr
DESCRIPTION
Unit has Over-
Heated
not Flashed
not ready
POSSIBLE CAUSE
This can happen under extreme use or if the
unit vents have been covered or the fan has
failed. Check the conditions below. Should
reset after a short period of cooling.
-
tubes life, or if it has not been used for some-
time, particularly at low powers. Try increasing

see if the fault clears.
This is accompanied by a warble from the
sounder, if on, and warns of a possible under

has occurred before the unit has fully charged.
In the event of an OH indication please check the following and rectify as shown:
CONDITION
Case vents obstructed:
Excessive ambient temperature:
Flash rate excessively fast:
STEPS TO RECTIFY
Clear vents of obstruction.
Lower the temperature or move to a
cooler area.